TROUBLE-SHOOTING GUIDE
|
|
SYMPTOM
|
CAUSE
|
CORRECTION
|
|
|
LCD
Display is blank
|
1.
Power is off to the Ec Controller
|
|
Re-establish power to the controller. If
the current time is not shown, or your program is no longer in memory,
reprogram the controller.
|
|
2.
If under battery power, the controller may be in "sleep" mode.
|
|
Press any button to reactivate the
controller.
|
|
LCD
is partially or completely blank.
|
|
3.
An electrical surge or lightning strike may have affected the controller's
electronics.
|
Turn
off the controller and disconnect the 9 Volt battery. let the controller
sit for two or three minutes. Then reconnect the battery and restore power
to the controller. Reset the date and time as described beginning on Page
12 of the Manual.
|
|
|
|
It
the electrical surge did no permanent damage, the controller will accept
programming commands and function normally. It the controller does not
operate properly, contact Rain Bird Technical Assistance. In Europe, or
outside the United States call your Rain Bird Dealer
|
|
|
Display
shows a station operating, but no watering occurs
|
4.
The valve may have a defective diaphragm, a clogged pilot port or other
malfunction.
|
Check
and repair the valve.
|
|
|
Program
does not begin watering as scheduled.
|
5.
Programming dial is set to OFF position.
|
|
Set
the programming dial to AUTO.
|
|
6.
Start time has not been properly entered for the program.
|
|
Turn
the dial to PRGM START TIME and check the start times entered for the
program. If the start time is missing or incorrect, enter it as described
on Page 16 in the Manual.
|
|
7.
Today may not be set as a watering day for the Program.
|
|
If
today is a watering day for a program, the program letter appears in the
display. Turn the dial to WATER DAY to check the watering days for the
program. It necessary set watering days as described on Page 15 of your
Manual.
|
|
8.
Water supply may be shut off.
|
|
Make
sure water supply line has pressure.
|
|
A
particular station does not come on as scheduled.
|
|
9.
No run time has been set for the station
|
Turn
the programming dial to STATION RUN TIME to check the run times set for
the station. To add a run time, see Page 17.
|
|
|
10.
A short circuit in the Solenoid or valve wiring has disabled the station.
|
Identify
and repair the fault in the electrical circuit.
|
|
|
11.
A start time has not been entered for the station's assigned program
|
Turn
the dial to PRGM START TIME and check the start times entered for the
program. If the station's start time is missing, enter it as described on
Page 16.
|
|
|
Watering
starts when it should not.
|
12.
An unwanted program start time may have been entered.
|
Turn
the dial to PRGM START TIME and check to see if any programs have an
unwanted start time. See the instructions beginning on Page 16 for setting
and deleting start times.
|
|
|
Watering
does not stop as scheduled.
|
13.
Programs may have accidentally been set to overlap.
|
|
Check
to see if another program's start time began during the previous program's
run cycle. The overlapped program would immediately follow the earlier
one. Reprogram if necessary.
|
|
14.
A valve is stuck in the open position.
|
|
Turn
the programming dial to OFF and wait 10-20 seconds. If the irrigation does
not stop, shut off the valve manually and repair the valve.
|
|
LCD
display shows ERR
|
|
15.
The automatic circuit breaker has detected an electrical problem
|
The
"ERR" in the display indicates a short circuit or electrical
overload on a particular station. The station's number should also be
displayed. For example "2 Err" means the problem is in the
circuit for Station 2.
|
|
|
|
Usually,
the short circuit is in the solenoid on the electric valve, but shorts can
also occur in the wire connectors at the valve. Occasionally, nicked or
"skinned" field wires can cause a short. A large pump start
relay can also produce a momentary overload that may be detected by the
controller.
|
|
|
|
Locate
and repair the cause of the short circuit. See Diagnostic Circuit Breaker
on Manual Page 6 for instructions on clearing the problem indicator from
the display and testing the station.
|
|
|
LCD
display shows an ERR for a few seconds and then shows the station
operating for a few seconds.
|
16.
Same as Cause #15.
|
See
correction for Cause #15.
|
|
|
Replace 9 Volt
Alkaline Battery [Energizer] every 12 Months.
|
|